Start-Up Procedure

UMBC Observatory Wiki!

Start-Up Procedure

Terms
DC - Data Computer
CC - Control Computer
MDC - Motor Driver Chassis (Front Panel with buttons and switches)
Zenith - Straight-Up
LHS - left Hand Side
RHS - Right Hand Side

  1. In Dome (bring cameras)

    1. Set thermostat to lowest setting (exhaust fan should turn on)

    2. Ensure all cameras to be used are connected to power/data (where applicable)

    3. Ensure instrument rotator is connected 

  2. DC & CC - Login

  3. DC - Open browser and begin blog

  4. DC - Load "Blue Iris Admin" (located in Start Menu) & confirm that DFM Scope is at Zenith (or close near-about)

    1. This will need to be updooted when we add more cameras

  5. DC - Open Kinesis (Thor Labs Instrument Rotator)

  6. CC - Open "DFMTCS", "TheSky6", & "ASCOM Dome Control" (all located in Start Menu)

  7. MDC - Enable "MTR DRIVER CHASSIS", "DRIVES", "TRACK", "AUTO DOME", and unpress "HALT MOTORS" button (big red, top-right)

  8. CC - With 3 & 4, DFMTCS "Status" box should read "SETTING" and then clear

  9. CC - Set Tracking Rates (Setting Tracking Rate in DFMTCS)

  10. CC - ASCOM Dome Control: Click "Connect" on RHS; then enable checkbox "Slave Dome to Scope"

  11. CC - ASCOM Dome Control: Click "Open" and confirm with BlueIris that dome shutters open correctly

  12. CC - TheSky6 : "Telescope" > "Link" > "Establish" from top menu

    1. Verify white crosshairs are in center (i.e., at zenith)

    2. If they aren't: restart TheSky6 (This likely needs another page or smthn)

  13. CC - Navigate to DFMTCS → Telescope → Misc... → Open Mirror Doors (under Switches/Mirror Door tab)

    1. The MDC Mirror Door switch should always remain in "OPEN" position

  14. DC - Navigate to "Outlet Control" in browser bookmarks bar

    1. The credentials should auto-fill

    2. "Switch On" outlets for

  15. DC - Open two instances of "SharpCap" (located in Start Menu)

    1. From top menu, select "Cameras" and ensure the appropriate cameras are listed (e.g., "ASi294MM Pro")

  16. Likely next step is to move on to Pointing Procedure

Related content

Shutdown Procedure
Shutdown Procedure
More like this
How to Use the Telescope
How to Use the Telescope
More like this
Autoguiding Experimentation
Autoguiding Experimentation
More like this
Eileen/Erik/Roy
Eileen/Erik/Roy
More like this
Auto-Dome
More like this
Autoguide Option 3 Test
Autoguide Option 3 Test
More like this

Direct Questions/Concerns to Roy Prouty (roy.prouty@umbc.edu)