Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

If nothing else, the first six steps are most important.

Leave all cameras connected to power and data, unless otherwise directed by Roy or Eileen.

  1. DC - Ensure all activities have been recorded in blog
  2. CC - Slew Telescope to Zenith by ""
  3. CC - Close Mirror Doors
    1. Navigate to DFMTCS → Telescope → Misc... → Close Mirror Doors (under Switches/Mirror Door tab)
    2. The MDC Mirror Door switch should always remain in "OPEN" position (this allows DFMTCS control)
  4. CC - Close Dome Shutters by ""
    1. Verify with BlueIris
    2. Verify again in dome
  5. In Dome - Turn thermostat to highest temperature setting.
  6. MDC - Disable "MTR DRIVER CHASSIS", "DRIVES", "TRACKING", "AUTO DOME", and press "HALT MOTORS" button (big red, top-right)
  7. CC - Terminate TheSky6 link with telescope by "" and close
  8. CC - Unslave dome to scope, disconnect, close ASCOM Dome Control
  9. CC - Close DFMTCS
  10. DC - Navigate to "Outlet Control" in browser bookmarks bar
    1. The credentials should auto-fill
    2. "Switch Off" outlets 1-4
  11. DC - Ensure all activities have been recorded in blog – again
    1. Publish
  12. DC & CC - Logout
  13. Close/lock all doors