obs/astropol: Roy, Meyer, Onkar, David, Nathan
newspeople: 2
Spaces
433C, Dome
Goals
- test gam
- issue motor commands
...
- Start Up
- opened hatch
- ran new gam cable from telescope gam cable to control room where gam is
- opened dfm tcs
- turned on drives, mtr drive chasis, unhalted motors
- no joy in success issuing commands from dfm tcs
- restart
- closed dfm tcs
- flipped switches off on mtr driver chasis
- turned off and then back on gam switch
- reopened dfm tcs
- flipped on switches on mtr driver chasis
- dfmtcs→telescope→gam→communication
- gam communication status: "Success" and south filter wheel updated after manually moving it from position 3 to position 4
- Testing encoders over 37-pin cable
- Encoders going over 37-pin cable:
- South filter wheel position
- Manually changed south filter wheel position via wheel
- Sent "Update GAM Status" command via GAM panel
- It updated to the correct position
- Took a few more seconds (5s) to report "Success" in GAM Communication Window
- Rotating Mirror Position
- Rotating Mirror claims position 5
- DFM Manual (pg 21) says this means LOL We don't know. It only supports readouts 0-3
- after rotating in several positions, still reports position 5
- cannot get the encoder for this to respond
- Rotating Mirror claims position 5
- Translating Stage
- when stowed, reports 1
- when in center of mirror, reports 2
- this is CORRECT according to DFM manual and were checked via the GAM status information section on dfmtcs
- South filter wheel position
- Encoders going over 37-pin cable:
- Testing via multimeter
- Translating Stage
- PH265L-01B VEXTA Motor
- yellow and white are ground/common
- other wires are different phases
- tested if the motor generates power, it does 5-7 Volts AC
- with that being said, might be voltage dropoff at some point in this long a** cable
- PH265L-01B VEXTA Motor
- gam cable - the long one
- uninstalled and brought down to control room to test for continuity via multimeter
- good continuity in the cables we could test
- resistance at 0.7 ohms - basically nothing
- Translating Stage
- Next steps
- bring GAM into the dome and directly connect to the gam cable (not use gam extension cable) and see if we still get "5" for the rotating mirror positon
- also want to test and see if we can issue any motor commands and see something happen
- order 14 pin connector for primary filter wheel motor to test
Todo
- Need to buy AMP 14-pin connector for 2" filter wheel motor
- Need to buy new belt for 2" filter wheel
- Need to buy 25 pin serial connector (DB 25S serial connector)
...
- Remote ability to hit reset switch would be nice -meyer
- referencing chapter 3.9.2.5 in the Telescope Operations Manual
- referencing GAM WIRING DWG No 349-209 in the DFM Eng Manual